Thermaflow SS934 Cooler

SS934
Hydraulic Reservoir, Filter and Cooling System
Hydraulic Reservoir, Filter and Cooling System
SIZE:
Flow Rate = up to 30 gpm
Reservoir Size = 4 gallons
Basic Dimensions = 22” Long x 10” Wide x 22” Tall
Weight (dry) = 62 lbs (dry)
FEATURES:
Heat Rejection Rate = 10 Hp @ 30 gpm with 50°F Exitng Temperature Difference (ETD)
Fan motor = Hydraulic drive requires 2 gpm
Corrosion Resistant components with SS case
10 micron Filer Element
Adjustable Pressure Relief Valve 500-3000 psi
5" Oil Level Sight Glass
PORTS:
Suction Port = SAE-24 Female
High Pressure Port = JIC-12 Male
Return Port = JIC-12 Male
Drain Port = SAE-8
Flow Rate = up to 30 gpm
Reservoir Size = 4 gallons
Basic Dimensions = 22” Long x 10” Wide x 22” Tall
Weight (dry) = 62 lbs (dry)
FEATURES:
Heat Rejection Rate = 10 Hp @ 30 gpm with 50°F Exitng Temperature Difference (ETD)
Fan motor = Hydraulic drive requires 2 gpm
Corrosion Resistant components with SS case
10 micron Filer Element
Adjustable Pressure Relief Valve 500-3000 psi
5" Oil Level Sight Glass
PORTS:
Suction Port = SAE-24 Female
High Pressure Port = JIC-12 Male
Return Port = JIC-12 Male
Drain Port = SAE-8
Excessive heat in your equipment’s hydraulic system reduces the efficiency of your system and the life of your hydraulic oil, resulting in lower power and higher operating costs. The SS934 space efficient solution provides superior heat rejection, lowering the overall cost of ownership of your equipment.